Cisco Fixes Six NX-OS Flaw Groups Across Switches and Fabric Interconnects

By

1-minute read

What a defender needs to know

Cisco’s October 7 NX-OS hardening advisory fixes six weakness groups in MDS 9000, Nexus 3000/7000/9000 and the listed UCS fabric interconnects, including the 9108 100G. A vulnerable release is affected regardless of configuration. The access-control and out-of-bounds-write groups each reach CVSS 9.8, the maximum severity of a finding within that group. Cisco’s PSIRT is unaware of malicious use. The vendor says there are no workarounds.

Start with a hardware-and-release inventory, separating Nexus 9000 ACI mode from standalone NX-OS and UCS Manager managed mode from Intersight managed mode. Compare each running build with the Cisco fixed-release tables: standalone Nexus 3000/9000 first fixes are 10.3(10), 10.4(8), 10.5(6) and 10.6(4) by branch; ACI mode uses 16.0(9h), 16.1(6g) and 16.2(3g). MDS 9.4 starts at 9.4(5a) and Nexus 7000 8.4 at 8.4(14). UCS first fixes depend on management mode; the 4.3(6.260059) build applies only to the 9108 100G. Older branches marked for migration need a supported fixed release. Assign migration tickets for MDS 9.3 and earlier, Nexus 7000 8.3 and earlier, and UCS 4.2 and earlier; each needs a target supported by Cisco.

Limit management access to the admin paths that need it while scheduling the change. After installation, read the running build from the device or management console and match its family and mode to Cisco’s table. The expected result is a Cisco-listed fixed build for each affected device.