Cisco’s October 7 advisory, revised October 8, covers CVE-2026-76471, an NX-API input-validation flaw that can let an unauthenticated remote attacker run root code or crash and reload an affected device. The unauthenticated path concerns Nexus 3000 and standalone NX-OS Nexus 9000 switches with NX-API enabled and a vulnerable release. Cisco says NX-API is disabled by default on those switches. UCS 6300 fabric interconnects have a different path: the enabled-by-default UCS Manager XML API requires valid low-privilege credentials. Cisco PSIRT reports no known malicious use.
On Nexus, run show feature | include nxapi, identify switches reporting nxapi 1 enabled, and check management-interface HTTP reachability from the networks that can access them. Record each device’s actual platform and running NX-OS release, then use Cisco’s Software Checker to find its first fixed release. Restrict API access to trusted administration paths while planning the upgrade. Cisco offers a temporary Live Protect shield but recommends fixed software; it describes no feature-preserving workaround.
For UCS 6300, review XML API access and low-privilege credentials, then upgrade the 4.3 branch to at least 4.3(6j) or migrate 4.2 and earlier to a fixed release. After maintenance, verify the running release and API access policy on each affected device. Nexus 9000 in ACI mode and UCS 6400, 6500 and 6600 are outside Cisco’s affected list.